Human IgG antibody Laboratories manufactures the point-of-care sars pcr test reagents distributed by Genprice. The Point-Of-Care Sars Pcr Test reagent is RUO (Research Use Only) to test human serum or cell culture lab samples. To purchase these products, for the MSDS, Data Sheet, protocol, storage conditions/temperature or for the concentration, please contact SARS Pcr. Other Point-Of-Care products are available in stock. Specificity: Point-Of-Care Category: Sars Group: Pcr Test
Human IgG Quick test strip |
|
MyBiosource |
5x10Tests |
EUR 1180 |
Dengue IgG/IgM antibody Test |
|
Orient Gene |
25 Tests/Box |
Ask for price |
Typhoid IgG and IgM (S. typhi IgG + IgM) Rapid Test Kit |
|
Abbexa |
100 µl |
EUR 650 |
Typhoid IgG and IgM (S. typhi IgG + IgM) Rapid Test Kit |
|
Abbexa |
1 ml |
EUR 7200 |
Typhoid IgG and IgM (S. typhi IgG + IgM) Rapid Test Kit |
|
Abbexa |
200 µl |
EUR 2100 |
Pcr Test information
Cleveland Open Cup Flash Point Tester |
|
52-OFP101 |
Lab Expo |
1 Each |
Ask for price |
|
|
|
Description: 52-OFP101 is designed with quartz tube heater which is highly efficient and cost effective and used to trace many products. It is designed and made as per ISO 2592, ASTM 92 “Test Methods for Flash and Fire Point of Petroleum Products (Cleveland Open Cup Methods) ”. |
Cleveland Open Cup Flash Point Tester |
|
52-OFP102 |
Lab Expo |
1 Each |
Ask for price |
|
|
|
Description: Cleveland Open Cup Flash Point Tester 52-OFP102 is equipped with English man-machine interface. It can preset expected flash point temperature and other parameters which is reasonably designed, safe and convenient to operate. It is designed and made as per ISO 2592, ASTM 92 “Test Methods for Flash Point and Fire Point of Petroleum Products (Cleveland Open Cup Methods) . |
Cleveland Open Cup Flash Point Tester |
|
52-OFP103 |
Lab Expo |
1 Each |
Ask for price |
|
|
|
Description: Cleveland Open Cup Flash Point Tester 52-OFP103 is devised with microprocessor techniques, inbuilt with advanced system software as per ISO 2592, ASTM 92 “Test Methods for Flash Point and Fire Point of Petroleum Products (Cleveland Open Cup Methods), and “Asphalt Flash Point and Fire Point Test (Cleveland Open Cup Methods) ”. |
Automatic COC Flash & Fire Point Tester |
|
52-OFP200 |
Lab Expo |
1 Each |
Ask for price |
|
|
|
Description: 52-OFP200 is deliberately furnished to determine both flash point and fire point. It has a wide range of applications with a great market value. It is designed as per the standard ASTM D92, ISO2592, IP36 (Standard Test Method for Flash Point of Petroleum Products-Cleveland Open Cup Method) . |
Open Cup Flash Point Tester BPTL-203 |
|
BPTL-203 |
Biolab Scientific Ltd. |
Each |
Ask for price |
|
|
|
Description: Petroleum testing is the analysis during upstream, midstream, and downstream production processes of petroleum products. It is most commonly used to test petroleum product, its product components, byproducts of crude oil, fuel, natural gas, upstream oil and gas and other formats of petroleum. - Adopt split structure. Automatical correct influence of atmospheric pressure, and calculate corrected value. Automatic forced air cooling after test. |
LD-LCFP-A10/PMCC Flash Point Tester |
|
LD-LCFP-A10 |
Labodam Equipment Ltd |
1 Each |
Ask for price |
|
Description: Dimension: 420 x 350 x 350 mm Power supply: AC 220 V ± 10 %, 50 Hz Heating power: 0 ~ 600 W Stirring blade: 8 x 40 mm Stirring speed: 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B Relative humidity: ? 85 % Temperature range: 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C Ambient temperature: ? 35 °C Standard oil cup- Depth: 55.7 ~ 56.0 mm Total Power Consumption: 600 W Aperture of ignition device: 0.8 mm Sample temperature rising rate: 1 ~ 12 °C per minute Standard oil cup-Inner diameter: 50.7 ~ 50.8 mm Standard oil cup-Inner diameter: 50.7 ~ 50.8 mm Standard oil cup- Depth of Marked line on the oil cup: 33.9 ~ 34.3 mm |
Automatic Freezing Point Tester BPTL-256 |
|
BPTL-256 |
Biolab Scientific Ltd. |
Each |
Ask for price |
|
|
|
Description: Petroleum testing is the analysis during upstream, midstream, and downstream production processes of petroleum products. It is most commonly used to test petroleum product, its product components, byproducts of crude oil, fuel, natural gas, upstream oil and gas and other formats of petroleum. - The instrument can be used to test freezing point of engine coolants and condensation liquids. Automatically judge the freezing point temperature. According to the different configuration, it can be used to test the freezing point etc.indexes of jet fuel, engine coolant and its concentrated solution, it's a multipurpose freezing point tester. It's the floor stand structure, the work table-board is made of stainless steel, concise design, nice appearance, convenient usage, fully furnished. |
Closed Cup Flash Point Tester BPTL-207 |
|
BPTL-207 |
Biolab Scientific Ltd. |
Each |
Ask for price |
|
|
|
Description: Petroleum testing is the analysis during upstream, midstream, and downstream production processes of petroleum products. It is most commonly used to test petroleum product, its product components, byproducts of crude oil, fuel, natural gas, upstream oil and gas and other formats of petroleum. - Automatic forced air cooling after test. Flame size is adjustable. Protect program and self-diagnosis function. |
Dropping Point Tester (Oil bath) BPTL-270 |
|
BPTL-270 |
Biolab Scientific Ltd. |
Each |
Ask for price |
|
|
|
Description: Petroleum testing is the analysis during upstream, midstream, and downstream production processes of petroleum products. It is most commonly used to test petroleum product, its product components, byproducts of crude oil, fuel, natural gas, upstream oil and gas and other formats of petroleum. - The oil bath is composed of heat resistant beaker, heater and electric motor. The heating power can be adjusted continuously. The temperature in oil bath is uniform. Desktop structure. Easy to operate |
Automatic COC Flash Point Tester BPTL-234 |
|
BPTL-234 |
Biolab Scientific Ltd. |
Each |
Ask for price |
|
|
|
Description: Petroleum testing is the analysis during upstream, midstream, and downstream production processes of petroleum products. It is most commonly used to test petroleum product, its product components, byproducts of crude oil, fuel, natural gas, upstream oil and gas and other formats of petroleum. - The instrument adopts LCD screen to display. It is applicable to all petroleum products with flash points above 79°C and below 400°C except fuel oils. Differential coefficient detection.Automatically correct the system deviation. |
Automatic COC Flash Point Tester BPTL-235 |
|
BPTL-235 |
Biolab Scientific Ltd. |
Each |
Ask for price |
|
|
|
Description: Petroleum testing is the analysis during upstream, midstream, and downstream production processes of petroleum products. It is most commonly used to test petroleum product, its product components, byproducts of crude oil, fuel, natural gas, upstream oil and gas and other formats of petroleum. - It adopts an 8-inch IPS high-definition capacitive screen. Using 32-bit ARM processor and high-precision AD chip, the test data and parameters are recorded in real time and displayed by curve. It is applicable to all petroleum products with flash points above 79°C and below 400°C except fuel oils. Equipped with Bluetooth interface. The user can query test data anytime. Remote automatic upgrade to obtain the latest version, remote prediction, abnormal early warning, comprehensive evaluation and maintenance of instrument operation status. |
Automatic PMCC Flash Point Tester BPTL-238 |
|
BPTL-238 |
Biolab Scientific Ltd. |
Each |
Ask for price |
|
|
|
Description: Petroleum testing is the analysis during upstream, midstream, and downstream production processes of petroleum products. It is most commonly used to test petroleum product, its product components, byproducts of crude oil, fuel, natural gas, upstream oil and gas and other formats of petroleum. - It adopts an 8-inch IPS high-definition capacitive screen. Temperature rise, cover opening, ignition, detection and printing data are completed automatically, and the test arm rises and falls automatically. Electronic ignition, gas flame, automatic air cooling at the end of the test. |
LD-LOFP-A10/Open Cup Flash Point Tester |
|
LD-LOFP-A10 |
Labodam Equipment Ltd |
1 Each |
Ask for price |
|
Description: Flame: 3 to 4 mm Heater: Heated by an electric furnace Gas Tube: ?0.8 ~ ?1 mm Dimensions: 410 x 360 x 240 mm Thermometer: 0 ? ~ 360 °C Power Supply: AC 220 V ± 10 %, 50Hz Heating Power: 1000W Scale Division: 1 °C Power Consumption: ? 1100 W Relative Humidity: ? 85 % Ambient Temperature: ? 35 °C Inner Crucible-Height: 47 ± 1 mm Outer Crucible-Height: 50 ± 5 mm Inner Crucible-Material: Carbon structural steel Outer Crucible-Material: Carbon structural steel Inner Crucible-Scale Line: 12mm away from the rim of upper opening and 18mm away from the rim of upper opening Inner Crucible-Diameter Of Bottom: ?38± 1 mm Outer Crucible-Diameter Of Bottom: ?56 ± 2 mm Inner Crucible-Diameter Of Upper Opening: ?64 ± 1 mm Outer Crucible-Diameter Of Upper Opening: ?100 ± 5 mm |
Cleveland Open Cup Flash Point Tester BPTL-232 |
|
BPTL-232 |
Biolab Scientific Ltd. |
Each |
Ask for price |
|
|
|
Description: Petroleum testing is the analysis during upstream, midstream, and downstream production processes of petroleum products. It is most commonly used to test petroleum product, its product components, byproducts of crude oil, fuel, natural gas, upstream oil and gas and other formats of petroleum. - It adopts special heating furnace to ensure the safety of test. It is applicable to all petroleum products with flash points above 79°C and below 400°C except fuel oils. The heating power is continuously adjustable. It can meet requirements of test. The instrument is fully self-contained complete. The operator can do determination as long as connecting with coal gas or other civil gas. With fast cooling function, it can improve test efficiency. |
Cleveland Open Cup Flash Point Tester BPTL-233 |
|
BPTL-233 |
Biolab Scientific Ltd. |
Each |
Ask for price |
|
|
|
Description: Petroleum testing is the analysis during upstream, midstream, and downstream production processes of petroleum products. It is most commonly used to test petroleum product, its product components, byproducts of crude oil, fuel, natural gas, upstream oil and gas and other formats of petroleum. - It adopts technology of single chip microcomputer and LCD screen. It is applicable to all petroleum products with flash points above 79°C and below 400°C except fuel oils. The LCD screen has prompt menu, prompt type input for operation interface. It shows set parameters and real-time display sample temperature and other parameters. Press the record key when flash point appearing. The screen will display and save flash point value. It is newly design and small structure. It is equipped with wind-shelter and flame extinguishing cover which are accord with requirements of test. Accurate heating rate.The instrument can do test automatically. Operator only need to observe the flash point appearing. The cost performance is high. |